Hospital and Facility Model
Full automation & stand-alone process
24/7 – 365 days operation
Full compliance with 93/42/EEC MDD (Medical Device Directive),
PED (Pressurized Equipment Directive), CE medical certification, ISO 8573-1:2010, ISO 13485:2016, ISO 9001:2016, ISO 14001:2016 standards.
Purity: 90 - 99%
Oxygen outlet: (0.60-147.79 m³/h.)
Production of gas you need at anywhere and anytime.
No lack of oxygen due to the exhaustion of gas.
Rapid ROI (Rate of Investment) (1-2 years)
No need for constant spending (refilling, delivery, and transportation costs, etc.)
No safety risk arising from the transportation of high-pressure cylinders.
Safe delivery, controlled flow, and uninterrupted gas supply.
Overall cost reduced by up to 80% as compared to cylinders.
40% less energy consumption than other available oxygen generators.
Electricity used during operations: 380 V/50 Hz- 220 V/50 Hz
Operation temperature: (0-50°C)
Low Energy Consumption ≤ (1.0 kW/m³)
Low CO2 emission
Password-controlled access and alarm management for different program levels.
93/42/EEC MDD (Medical Device Directive), PED (Pressurized Equipment Directive) and CE medical certification, ISO 13485:2016, ISO 9001:2016, ISO 14001:2016 standards.
Overall cost reduced by up to 80% as compared to cylinders. 40% less energy consumption than other available oxygen generators̈. ̈No constant spending (refilling, delivery, and transportation costs, etc.)
Full automation & independenẗ process. Production of gas you need at anywhere and anytimë. No lack of oxygen due to the exhaustion of gas.
It compresses air to the desired pressure level.
It accumulates the required volume of air for the PSA generator
G-General Purpose Protection Filter: Removal of particles down to 1 micron including coalesced liquid water and oil providing a maximum remaining oil aerosol content of 0.5 mg/m³. Automatic discharge unit.
H- High-Efficiency Oil Removal Filtration: Removal of particles down to 0.01 micron including water and oil aerosols providing a maximum remaining oil aerosol content of 0.01 mg/m³. Automatic Discharge Unit
It removes moisture in the air (dehumidify) by cooling.
7” Touch Color Screen.
Control monitor, electronic control panel (Liquid and dust-proof)
When ion exchange bed is filled with this, N2 molecules are trapped and O2 molecules continue to flow.
It flows from PSA generator towards production tank and is ready for use.
It can be adjusted between 4 and 6 bar.
(0.001 Micron)
It is used to filter oil vapor and to remove hydrocarbon odor. The remaining oil amount in the filter outlet is 0.003 mg/m3 @ 21oC. (If there are G and H grade filters at the inlet)